10.17 Holding brake connection diagram
FXM synchronous motor
PE
(R)
L1
(S)
L2
(T)
L3
N
- S1
MECHANICAL MAIN SWITCH
FXM MOTOR
3
Z
BRAKE
F. H10/31
Connection diagram for the holding brake of an FXM synchronous servo motor.
FKM synchronous motor
PE
(R)
L1
(S)
L2
(T)
L3
N
- S1
MECHANICAL MAIN SWITCH
FKM MOTOR
3
Z
BRAKE
F. H10/32
Connection diagram for the holding brake of an FKM synchronous servo motor.
BR
230 VAC
24 VAC
E
F
+24 VDC
E
0 VDC
F
400 VAC
BR
4
5
Important. Power the holding brake with a power
supply that provides a continuous, stabilized voltage
+24 VDC
4
of 24 V DC. To ensure safe operation in the event of
5
large temperature variations, the coil must be
0 VDC
powered with stabilized direct current.