RS-232 serial line cable between a VT and a drive
Once the project has been transferred from the PC to the VT (ESA), the
video terminal may be connected to a single drive, hence establishing
communication via the MSP serial port of the VT and the drive's RS-232
serial port.
NOTE. When mentioning a drive, it means any model of the FAGOR
catalog, i.e. AXD, SPD, ACD, SCD, MMC and CMC models.
MANDATORY. The RS-232 serial line can only be used between the ESA
VT and a single drive. The arrow of the drive's node selecting rotary switch
(NODE SELECT) must be pointing at 0.
It is now possible to handle and control from the Video Terminal the
process application by communicating with the connected drive. The
connection cable to be used is described next.
NOTE. The adapter RS232/RS422 BE is not required in any case.
RS-232 cable
DRIVE
9-pin Sub-D,
type female
connector
F. H7/18
RS-232 serial line connection between the VT from ESA and a drive · without
adapter ·.
The connection cable has the following connectors at its ends:
D
1
6
9
5
to drive
(Sub-D, F9)
These two connectors are at both ends of the RS-232 cable.
F. H7/19
D. Connector of the RS-232 cable for direct connection to the drive.
B. Connector of the RS-232 cable for direct connection to the VT from ESA.
The connection is:
D
Sub-D, F9
Signal
Pin
RxD
2
TxD
3
DTR
4
DSR
6
RTS
7
CTS
8
CHASSIS
5
To drive
D. Note that the pairs of pins 4-6 and 7-8 must be jumpered.
B. Note that the pairs of pins 4-5, 7-25 and 15-18 must be jumpered.
F. H7/20
RS-232 connection between a VT and a drive · without adapter ·.
25-pin Sub-D,
to the VT panel
type male
connector
to the VT panel (ESA)
(Sub-D, M25)
B
RS-232 cable
Sub-D, M25
Maximum length: 15 meters
To the VT panel (ESA)
   Cables
7.
(ESA)
1
14
25
13
B
Pin
Signal
TxD
2
3
RxD
15
18
DDS
4
TRS
HARDWARE
5
CTS
25
GND
7
Ref.1912
· 257 ·