  Power supplies
2.
94
DDS
HARDWARE
Ref.1912
· 50 ·
PS-25B4
X3 CONNECTOR
1
3
Phoenix 7.62 mm
PS-25B4
X4|X5|X6 CONNECTORS
1
3
1
3
1
3
Phoenix 5.00 mm
F. H2/13
Connectors X3|X4|X5|X6 of the auxiliary power supply integrated into the
PS-25B4.
The gap and tightening torque and sections of the screws of the plug-in
connectors for X3 and X4|X5|X6 are given by the table:
T. H2/12 Plug-in connector for X3. Technical data.
Connector data
Nr of poles
Gap (mm)
Min/max tightening torque (N·m)
Screw thread
Min./max. section (mm²)
Rated current In (A)
Wire data
1x
Length to strip (mm)
T. H2/13 3 identical plug-in connectors for X4/X5/X6. Technical data.
Data of each connector
Nr of poles
Gap (mm)
Min/max tightening torque (N·m)
Screw thread
Min./max. section (mm²)
Rated current In (A)
3x
Wire data
Length to strip (mm)
INFORMATION. In cases of micro-surges or total loss of mains power, this
i
module guarantees stable and maintained 24 V DC while the motors are
being stopped. This is an absolute must in order to comply with the EC
requirement for the machine.
1
2
3
1
2
3
PS-25B4
3
7.62
0.5/0.6
M3
0.2/2.5
12
7
PS-25B4
3
5.08
0.5/0.6
M3
0.2/2.5
12
7
L1
400/460 V AC
L2
400/460 V AC
+24 V DC
0 V