  Power supplies
2.
94
DDS
HARDWARE
Ref.1912
· 90 ·
A 1.25 A fuse protects the internal circuits.
NOTE. Remember that the internal circuits of PS-65A non-regenerative
power supplies must be powered by an auxiliary 24 V DC power supply,
"APS-24"; that's why its control connector has three terminals more than
connector X6 of the RPS.
The following table shows the values for gap, tightening torque, sections of
the screws and other data of the plug-in connector for X6.
T. H2/35 Plug-in connector for X6. Technical data.
Connector data
Nr of poles
Gap (mm)
Min./max. tightening torque (N·m)
Screw thread
Min./max. section (mm²)
Rated current In (A)
Wire data
1x
Length to strip (mm)
The next table shows the signals and other considerations related to each
pin of connector X6:
T. H2/36 Connector X6. Description of the pins.
1
ERROR RESET
2
N.C.
3
GND
4
PWM ENABLE
SYSTEM SPEED
5
ENABLE
6
SYSTEM OK
7
SYSTEM OK
RPS-80 | RPS-75 | RPS-45 | RPS-20
0.5/0.6
0.2/2.5
System error RESET input
(24 V DC; 4.5-7 mA).
Not Connected
0 volts reference for digital inputs.
Error RESET (1) and System Speed Enable (5).
Safety.
Power bus voltage enable input (24 V DC).
General system speed enable.
(24 V DC; 4.5-7 mA).
Contact indicating module status.
It opens in case of failure.
Limit 1 A at 24 V.
7
5.00
M3
12
7