   Installation
How to plug and unplug the Ballast connector
On ACD|SCD|CMC 1.08|1.15 drives ,
to connect an external Ballast
resistor, first insert the terminals into the poles identified as Re and L+ of
the connector with plug-in terminals and tighten each screw (slotted head
0.6x3.5 mm) with a tightening torque of 0.5 0.8 N·m. To connect the
internal Ballast connector, first insert the wire jumper in the poles identified
as Ri and L+ and proceed the same way.
Now plug in the corresponding female connector (bottom of the module) and
press on it until hearing a click. Note that you won't be able to extract it even
8.
by pulling at it . To unplug it, push the orange side tabs up of the connector with
plug-in terminals and while keeping in that position, pull at it.
On ACD|SCD|CMC 1.25|2.35|2.50 and SCD 2.75 drives
, to connect
an external Ballast resistor, first insert the terminals into the poles identified
as Re and L+ of the connector with plug-in terminals and tighten each
screw (slotted head 0.6x3.5 mm) with a tightening torque of 0.5¸0.8 N·m.
Observe that it is not possible to connect an internal Ballast resistor.
Now plug in the corresponding female connector (bottom of the module) and
press on it until hearing a click. Note that you won't be able to extract it even
by pulling at it . To unplug it, push the orange side tabs up of the connector with
plug-in terminals and while keeping in that position, pull at it.