Fagor DDS Series Hardware Manual page 282

Table of Contents

Advertisement

   Installation
8.
310
DDS
HARDWARE
Ref.1912
· 282 ·
H o w t o i n s t a l l A N e x t e r n a l B a l l a s t r e s i s t o r w i t h i n t e r n a l
thermostat and fan
WARNING. Therefore, the resistor should be mounted away from the rest of
the modules or even outside the electrical cabinet, always vertically and away
from cables and other temperature sensitive material.
Always install it vertically
Re
L+
Ballast resistor
connection terminals
Diagram
Connect the fan connection terminals to an
outlet of the electrical cabinet, single phase
5 0/60 Hz , 22 0/240 V AC. Consu mptio n:
0.15/0.13 A, 23/20 W.
Connect the Ballast resistor terminals to the Re and L+ terminals of the
terminal strip of the Ballast of the power supply or compact drive
accordingly.
F. H8/16
Installing AN external Ballast RESISTOR with internal thermostat and fan.
Two FASTON
plug-in male
terminals with
a tab size of
2.8 x0.5 mm for
fan connection
Tk connection
terminals of the
internal thermostat
Connect either one of the two
pins to +24 V DC of the
external power supply of the
electrical cabinet and the
other one to a PLC input.
Important. Remember to
manage the chosen PLC input
in the PLC program to generate
an error when exceeding the
limit temperature (160 °C)
detected by the sensor and to
open the contact.