   Cables
7.9 RS-422 serial line
7.
DDS
HARDWARE
Ref.1912
· 258 ·
FAGOR does NOT supply these cables. Nevertheless, these are the
connection diagrams. Note that the RS232/RS422 BE adapter may be
used to connect the RS-232 or RS-422 serial line with a VT panel from
ESA.
NOTE. The user is free to use this FAGOR adapter or not. But, it should be
used unless indicated otherwise because it makes the connection a lot
easier.
RS-422 serial line cable between a VT and several drives
· without adapter ·
NOTE. Only for MMC or CMC drives.
to the VT panel
(ESA)
F. H7/21
RS-422 serial line connection between a VT from ESA and several MMC or
CMC drives · without adapter ·.
RTS
4
+ 5 V ( 16 )
CTS
5
470 
1/4 W
23
TxRS422 + OUT
330 
1/4 W
12
TxRS422 - OUT
470 
1/4 W
GND ( 7 )
+5 VCC
16
GND
7
+ 5 V ( 16 )
470 
25
1/4 W
RxRS422 +IN
13
330 
1/4 W
RxRS422 - IN
24
470 
15
1/4 W
GND ( 7 )
18
CHASSIS
TO THE VT PANEL (ESA)
1
14
Sub-D, M25
Frontal view
25
13
F. H7/22
RS-232 serial line cable between a VT from ESA and several MMC or CMC
drives · without adapter ·.
If the user chooses to use the RS232/RS422 BE adapter, the RS-422 serial
line must be connected as instructed in the following section. This chapter
has already described all the details on this adapter as well as the pinouts
of its ends.
RS-422 cable
MMC
MMC
or
or
CMC
CMC
1
2
.....................
to DRIVE 1
to DRIVE N
To CMC or MMC 1
To CMC or MMC N
(Sub-D, F9)
(Sub-D, F9)
MMC
or
CMC
n
330 
1/4 W