How to install TWO extern al Ballast resistor in parallels
Always install both resistors vertically
Diagram for 2 r esistors in paral lel wit h fan and i nt ernal t her mostat
Take the connection terminals of each fan to an outlet of the electrical cabinet, single
phase 50/60 Hz, 220/240 V AC. Consumption: 0.15/0.13 A, 23/20 W.
Connect as shown in the image the terminal
labeled + 24 V DC to an external 24 V DC
power supply of the electrical cabinet and the
other one labeled PLC INPUT to a PLC input.
I M P O R T A N T . R e m e m b e r t o m a n a g e t h e
chosen PLC input in the PLC program to
generate an error when exceeding the limit
temperature (160 °C) detected by the sensor
and to open the contact.
D i a gr a m f o r 2 r e s i s t or s i n p a r a l l e l w i t h an i n t e r na l t he r m o st at
and no fan
Connect as shown in the image the terminal
labeled +24 V DC to an external 24 V DC
power supply of the electrical cabinet and
the other one labeled PLC INPUT to a PLC
input.
IMPORTANT. Remember to manage the
chosen PLC input in the PLC program to
generate an error when exceeding the limit
temperature (160 °C) detected by the
sensor and to open the contact.
F. H8/17
Installing TWO external Ballast resistors in parallel.
Conn ec t as sh own i n th e
image the indicated termi-
nals to the Re and L+ termi-
nals of the terminal strip of
the Ballast of the power sup-
ply (only PS-65A or XPS-
65).
Connect as shown in the image
the indicated terminals to the Re
and L+ terminals of the terminal
strip of the Ballast of the power
supply (only PS-65A or XPS-65).