Lights indicating the status of the main power supply
The regenerative power supply XPS-25 has the following lights on the front
panel to indicate the status of the main power supply:
 FAULT BLINKING. The blinking red led indicates that there are no
errors and that one or several mains phases are missing.
 FAULT turned ON. The steady red led on indicates that there is an
error. The error is indicated on the display of the drives.
 FAULT turned OFF. The led off indicates that there is no error and that
all mains phases are OK.
 REGEN. The led is lit when the module is working in energy regenerating
mode.
 DC BUS ON. The green led indicates that the module is supplying all its
power at the bus.
INFORMATION. For further detail on these indicator lights, see the
i
combination table for interpretation in the description of the E305 on the
error listing shown in chapter
"man_dds_soft.pdf" manual.
Lights indicating the status of the auxiliary power supply
The regenerative power supply XPS-25 has the following lights on the front
panel to indicate the status of the integrated auxiliary power supply:
 RESET. Initializes the auxiliary 24 V DC power supply.
 OVER VOLTAGE. The red led indicates that there is an over-voltage
error at the 24 V DC output or due to over-temperature.
 OVER CURRENT. The red led indicates that there is an over-current
error at the 24 V DC output.
 ON. The green led it indicates that there are 24 V DC at the output.
14. ERROR CODES AND MESSAGES
  Power supplies
2.
of the
DDS
HARDWARE
Ref.1912
· 57 ·