Fagor DDS Series Hardware Manual page 286

Table of Contents

Advertisement

   Installation
8.
310
DDS
HARDWARE
Ref.1912
· 286 ·
How to install TWO resistors ER+TH-18/1100 in parallel to the BPM
module
Always install both resistors vertically
Diagram for 2 resistors in parallel with an external thermostat
Connect according to the figure the terminal
labeled +24 V DC to an external 24 V DC
ER+TH-18/1100
power supply of the electrical cabinet and the
PLC INPUT to a PLC input.
IMPORTANT.
Remember to manage the chosen
PLC input in the PLC program to generate an
error when exceeding the limit temperature
(200°C) detected by the sensor and to open
the contact.
Connect the R-R terminals
of the resistor to the connec-
tion terminals R2-R2 of the
Ballast connector of the
BPM module.
F. H8/19
Connection of TWO external Ballast RESISTORS in parallel to the bus
protection module, BPM.
ER+TH-18/1100
Connect the R-R terminals of the
r e s i s t o r t o t h e c o n n e c t i o n
terminals R1-R1 of the Ballast
connector of the BPM module
Connector of the Ballast of the
BPM module

Hide quick links: