4.1 Mains filters
4.
200
DDS
HARDWARE
Ref.1912
· 182 ·
In order to comply with European Directive 2014/30/UE on Electromagnetic
Compatibility, it is mandatory to insert a mains filter. Particularly, the
standard IEC 61800-3 for category C3 and the standard IEC 61800-5-2 for
immunity.
The mains filters of the FAGOR catalog are referred to as MAIN FILTER.
They are installed between mains and the DDS system (modular or
compact) in order to reduce conducted disturbances caused by the drive
down to the levels indicated by the standard mentioned earlier and, at the
same time, make it immune to transient over-voltage like bursts or voltage
pulses.
Outside look
F. H4/1
Mains filters. Outside look.
Technical data
T. H4/1 Mains filters. Technical data
MAIN FILTER
Rated voltage
Rated current
(rating @ 50°C/122°F)
Approx. mass kg/lb
Rated leak current
Max. leak current
Power loss
Sealing
T. H4/2 Mains filters. Technical data of the connection terminals.
MAIN FILTER
Max. tightening torque (N·m)
Terminals min./max. section (mm²)
i
Note that this filter must be mounted near the drive.
42A-A
75A-A
130A-A
3-ph, 380/480 V AC (50/60 Hz)
42 A
75 A
130 A
2.8/6.2
4.0/8.81
7.5/16.5
0.50 mA
0.50 mA
0.75 mA
27 mA
27 mA
130 mA
19 W
20 W
40 W
IP 20
IP 20
IP 20
42A-A
75A-A 130A-A 180A-A
1.8
2.3
1/10
0.5/25
INFORMATION.
180A-A
180 A
11.0/24.2
0.75 mA
130 mA
61 W
IP 20
8.0
18.0
16/50
35/95