Diagram for general connection to mains
WARNING. When using an isolating transformer, the secondary must be
connected in star and its middle point must be connected to GND.
PE
L1
- F3
L2
- F4
L3
- F5
N
IT A MUST TO USE FUSES
- S1
MECHANICAL
MAIN SWITCH
Note. Observe that having the main key -S1 closed, although the power
contactor - KM1 is open, the internal 24 auxiliary power supply of the
unit remains connected through its connector X1 to feed the control
circuits of the drive.
F. H10/26
ACD/SCD compact drive, CAN. Diagram for general connection to mains.
Diagram of the maneuver
Important.
T h e r e l a y K A 3 u s e s d e l a y e d
d e a c t i v a t i o n ( t s e c o n d s )
maintaining the DRIVE ENABLE
control signal active for a few
seconds to maintain motor torque
while the vertical axis holding
brake is enabled.
See parameter GP9 in the
"man_dds_soft.pdf" manual.
Note.
C N C E M E R G . w i l l a l w a y s b e
assigned to I1/O1 of the PLC with
an 8055/55i CNC. With an 8070
CNC, it may be assigned to any I/O
o f t h e P L C . T h e c o n t a c t s
associated with relays - KA3, - KA4
and - KA6 are shown in fig.
and the contactor - KM1 in
H10/25
fig.
.
F. H10/26
F. H10/27
Compact DDS system. ACD/SCD, CAN. Diagram of the maneuver.
- Q1
DIFFERENTIAL
BREAKER
TO THE X1
CONNECTOR
+24VDC
X+
X-
KA1
Z+
Z-
KM1
ON
EMERG.
STOP
DR.X
OK
OFF
DR.Z
OK
I1 PLC
-KM1
-KA3
CNC EMERG.
DRIVE
O1 PLC
ENABLES
-KA1
F.
EMERGENCY LINE
GND
MAIN FILTER 42A-A
L1
L2
L3
L2
TO THE POWER CONNECTOR
ACD/SCD COMPACT DRIVES
3x 400-460 VAC
KM1
KM1
KA3
KA3
CNC
CNC
ON
OFF
ENABLE
ENABLE
Green
Red
X
Z
DELAY OFF
t seconds
-KA4
-KA6
ON
OFF
TO SPEED ENABLES
Connection diagrams
L1
L2
L3
10.
- KM1
CONTACTOR
L1
BRK
BRAKE
CONTROL
(See GP9)
HARDWARE
DDS
Ref.1912
· 353 ·