PS-25B4 module
Technical data
T. H2/4
Technical characteristics.
Line voltage
Line frequency
Mains power consumption (400 V AC)
Minimum connection cable section ·1·
VBUS
Power DC BUS voltage,
Rated (peak) output current ·2·
Rated (peak) output power
Internal Ballast resistance (power) ·2·
Energy pulse to be dissipated
Ballast circuit ON/OFF
Minimum external Ballast resistance
Filter capacity
Energy stored in the capacitors
Maximum "SYSTEM OK" contact voltage
Maximum "SYSTEM OK" contact current
Width in mm | in
Approx. mass in kg | lb
Power dissipated at maximum load
Depending on the rated operating power.
·1·
For high temperatures, refer to derating graphs ·power reduction graph·.
·2·
Connection of the auxiliary power supply
Output voltage, maximum current
Line voltage INPUT
Line frequency
Mains consumption
Maximum Inrush current
DC BUS consumption
Maximum voltage at the DC BUS
T. H2/5
Ambient conditions and other characteristics.
Ambient temperature
·1·
Storage temperature
Maximum humidity
Maximum installation altitude
Operating vibration
Shipping vibration
Sealing
Protections
For high temperatures, refer to derating graphs ·power reduction graph·.
·1·
PS-25B4
3-ph, from 400 (1-10 %) V AC to 460 (1+10 %) V AC
48 ... 62 Hz
36 A
10 mm²
RATED
565/650 V DC
45 A (135 A, 1 s)
25 kW (75 kW, 1 s)
16.5  (500 W)
6 kW (0.2 s)
768/760 V DC
16.5 
820 µF, 900 V DC
0.5 C·V²
125 V AC, 150 V DC
1 A
77 | 3.03
6.0 | 13.2
180 W
24 V DC (5 %), 10 A
From 400 (1-10 %) V AC to 460 (1+10 %) V AC
48 ... 62 Hz
0.72 A (400 V AC); 0.63 A (460 V AC)
23.9 A (460 V AC)
0.485 A (565 V DC); 0.44 A (650 V DC)
790 V DC
PS-25B4
0°C/+45°C (32°F/113°F)
-25°C/+60°C (-13°F/+140°F)
< 90 % (non condensing at 45°C/113°F)
2 000 m (6 561 ft) above sea mean level
1 g
1.5 g
IP 2x
Over-voltage, heat-sink temperature, hardware error,
Ballast overload.
  Power supplies
2.
DDS
HARDWARE
Ref.1912
· 39 ·

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents