Connectors
Layout
ACD|SCD 1.08/1.15
These drives have the following connectors:
SL1
SL2
F. H3/107
ACD|SCD 1.08|1.15 compact drives. Connectors.
1.
Power connector for motor (U, V, W) and mains connection (R, S, T).
Note. RST has been the classic nomenclature for mains phases. L1L2L3 is its equivalent nowadays.
2.
Connector for the internal (Ri) or external (Re) Ballast resistor and for accessing the bus (L+, L-).
X1. Connector for the internal 24 V DC power supply (2-ph. with line voltage V AC).
X2. Connector for the basic control signals.
X3. Connector with two possible uses:
• as output of the encoder simulator.
• as input of the direct feedback for the position loop.
X4. Connector for motor feedback connection (encoder).
X5. Connector for RS-232 serial line connection.
X6. SERCOS-II or CAN interface connector.
X7. Connector for external acknowledgment of the status of the safety relay.
SL1. Slot for the cards A1, 16DI-8DO and 8DI-16DO.
SL2. Slot for the cards 16DI-8DO and 8DI-16DO.
top view
X1
X3
X4
X6
X5
BOOT button.
Software update. SERCOS|CAN
transmission speed selection.
bottom
view
1
RESET button
WARNING. AC touch current greater
than 3.5 mA. Install a ground wire
with a section of at least 10 mm² (Cu)
or 16 mm² (Al).
X6
or
2
  Drives
3.
X7
X2
DDS
HARDWARE
Ref.1912
· 151 ·