Fagor DDS Series Hardware Manual page 18

Table of Contents

Advertisement

Manual reference
0706
0710
0802
0806
0811
0905
1003
1107
1109
1209
1305
1307
1406
1502
1601
1605
20
1702
1710
1711
1807
DDS
HARDWARE
Ref.1912
· 18 ·
Events
New VECON-3 board
Sales models of the glass fiber optic cable SF0-V-FLEX
New ER-18/1000+FAN resistor with fan.
No new hardware has been implemented.
New compact drives: ACD/SCD/CMC 2.50.
There are now 3 switches for selecting the ballast resistor on PS-25B4
power supplies.
New CAPMOTOR-2 board.
The choke RPS-75-3 replaces the choke RPS-75.
There are now 3 switches for selecting the ballast resistor on PS-65A
power supplies.
The following are being replaced:
External 18/1800 W Ballast resistor that is supplied as an accessory
in certain units for 18/1800W with internal thermostat.
External Ballast resistor ER-18/2200 by ER+TH-18/2200 with internal
thermostat.
External 24/750W Ballast resistor that is supplied as an accessory in
certain units for 24/750W with external thermostat.
Changing the power connector for motor connection at SPD 3.200
drives.
The external ballast resistor with fan ER-18/1000+FAN has been
replaced with the new ER+TH-18/1000+FAN with fan and external
thermostat.
The auxiliary APS 24 power supply has been modified and it can now
be connected to the DC bus of the PS, XPS and RPS power supplies.
New regenerative regulated power supply RPS-80.
New modular spindle drive SPD 3.250.
No new hardware has been implemented.
No new hardware has been implemented.
Functional safety. STO safety function.
New spindle compact drive SCD 2.75.
New CHOKE XPS-65-A that replaces the CHOKE XPS-65.
New VECON-4 board.
The Ballast aerial connector has been changed on all compact drives.
New capacitor module ·CM-1.75· (replaces the ·CM-1.60·).
RPS power supplies. RPS mode (boost) and RB6 mode (rectifier).
Mains filter. "MAIN FILTER 75A" for RPS-45.
Temperature sensor isolation adapter ·TSIA-1·.
Bus Protection Module ·BPM·.
Reorganization of texts for electrical safety and functional safety.
New mains filter: ·MAIN FILTER 130A-A· for PS-65A.
New commercial models -MDU (dual-use).
Mains filter ·MAIN FILTER 42A-A· for PS-25B4, XPS-25, RPS-20, and
ACD/SCD x.x replacing MAIN FILTER 42A.
Mains filter ·MAIN FILTER 130A-A· for XPS-65 and RPS-75 replacing
MAIN FILTER 130A.
Mains filter ·MAIN FILTER 75A-A· for RPS-45
TÜV SÜD FUNCTIONAL SAFETY certificate update.
No new hardware has been implemented.
Changing the sensor position of the thermostat for the braking resistors
ER+TH-...+ FAN.
Equipment for working in industrial graphite environments:
Power supplies: PS-25B4-C, RPS-20-C,
Drives: AXD 1.15-S0-2-C, AXD 1.25-S0-2-C, AXD 1.35-S0-2-C
CA-D1-D4 adapter cable for the connection of the linear motor or
torque motor feedback to the motor feedback board of the drive.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents