Fagor DDS Series Hardware Manual page 148

Table of Contents

Advertisement

  Drives
3.
180
DDS
HARDWARE
Ref.1912
· 148 ·
I (Arms)
In
20
19
18
17
35
40
45
50
(95)
(104) (113) (122) (131) (140)
F. H3/96
Current derating on ·ACD|CMC 2.50· drives for fc = 8 kHz.
Drive for a synchronous|asynchronous motor working as a spindle
The following graphs show the maximum rms current in continuous duty
cycle (that is, the rated one) depending on the switching frequency of the
power transistors that the drives for asynchronous motors can supply in a
temperature range between 5°C/41°F and 60°C/140°F.
 For a switching frequency fc = 4 kHz
I (Arms)
Imax
11
10
9
8
35
40
45
50
(95)
(104) (113) (122) (131) (140)
F. H3/97
Current derating on ·SCD 1.15· drives for fc = 4 kHz.
I (Arms)
18
Imax
17
16
15
35
40
45
50
(95)
(104) (113) (122) (131) (140)
F. H3/98
Current derating on ·SCD 1.25· drives for fc = 4 kHz.
I (Arms)
Imax
28
26
24
22
35
40
45
50
(95)
(104) (113) (122) (131) (140)
F. H3/99
Current derating on ·SCD 2.35· drives for fc = 4 kHz.
ACD|CMC 2.50
T ambient
° C
35
40
Tambient
45
°C (°F)
50
55
60
55
60
SCD 1.15
T ambient
° C
35
40
45
Tambient
50
°C (°F)
55
55
60
60
SCD 1.25
T ambient
° C
35
40
45
Tambient
50
°C (°F)
55
55
60
60
SCD 1.25
T ambient
° C
35
40
45
Tambient
50
°C (°F)
55
55
60
60
In
° F
A
95
20.0
104 20.0
113
20.0
122 19.1
131 17.8
140 16.4
Imax.
° F
A
95
10.6
104
10.6
113
10.6
122
9.9
131
9.1
140
8.2
Imax.
° F
A
95
17.5
104
17.5
113
17.5
122
16.8
131
15.9
140
14.9
Imax.
° F
A
95
28.0
104
28.0
113
28.0
122
27.2
131
24.5
140
22.7

Hide quick links:

Advertisement

Table of Contents
loading