   Connection diagrams
10.18
POWER SU PPLY
FAGOR
10.
OUTPUT 24 V DC
CH ASSI S
T H E ST AR/D ELT A
SWI T CH I S M AN AGED
BY T H E PLC PROGRAM
AT T H E 8070 CN C
Notes. The I/O selected in the figure have been chosen arbitrarily. In general any Ixx and Oxx may be used always
matching the ones used in the PLC.
It is very common to choose I1 and O1 for the external emergency. Therefore, we suggest not to use them for this
application. If they are going to be used, make sure that they have not been set to be used as emergency input and
output.
Important warnings
1. Either an external auxiliary power supply or a FAGOR power supply may be used to supply the 24 V DC.
358
2. To brake the motor in a controlled way during a power failure, make sure that 24 V DC will be supplied to
3. When using a compact SCD drive to govern a spindle motor, you must necessarily install an external auxiliary
Sizing of -KM1 and - KM2 power contactors
- KM1 contactor: I
DDS
- KM2 contactor:
HARDWARE
Note. See these currents in chapter 6. Selection, of the FM7/FM9 motor manual.
Sizing of motor power cables
MPC- 4xN
Ref.1912
MPC- 4xN
Note. See the necessary cable section according to table of the chapter 4. Installation of the FM7/FM9 motor manual.
F. H10/33
Diagram of on-the-fly Y/D (start/delta) connection switching for FM7-XXXX-XXX-E03|HS3 motors.
· 358 ·
On-the-fly start/delta connection switching on FM7 spindles, E03|HS3 series
D RI VE SPD
F AGOR
U
V
W
ST AR connecti on
U
U1
*
24 V (of the FAGOR power volta ge)
24 V
0 V
* WARNING. Never connect an external
auxiliary power supply and a FAGOR
power supply at the same time.
*
0 V (of the FAGOR power vol ta ge)
CAN Fa gor
I N T ERFACE
Never connect both at the same time !
contactors - KM1 and - KM2 and relays - KA3 and - KA4. This situation is ensured if you have installed a
FAGOR power supply next to an SPD modular drive. If you have installed an external auxiliary 24 V DC power
supply, you must make sure that this condition is ensured.
power supply to provide the 24 V DC. These compact drives do not have an output 24 V DC connector.

> I
(
)
(KM1)
N
> (1/
) I

I
3
N
(KM2)

N
: section supporting I
1
1
N
: section supporting I
2
2
MPC-4xN
2
D ELT A connecti on
V
W
U
V
W
V1
V1 W2
V2
U2
W2
V2
W1
U1
U2
W1
- KA1
DIGITAL OUTPUT
POWER SUPPLY
+24V
CHASIS
O1
GND IN
O2
GND IN
X1
O3
+24V IN
O4
SYSTEM
X1
O5
READY
O6
O7
OVER VOLTAGE
Auxi l i a r y r el a ys - KA3, - KA4. e.g. RP821024
O8
+5V
GND
F l ywheel di odes D 3, D 4. e.g. 1N 4934
O10
SYSTEM READY
+24V.
+5 OVER CURRENT
O9
+5 ERROR
O10
POWER
O11
O11
O12
X2
O13
O14
O15
RESET
O16
GND
C
ADDRESS
DIGITAL INPUT
ADD MSB
N.C.
LINE TERM
I1
0
1
I2
I3
I4
X1
GND
I5
CAN L
I6
X2
SHIELD
I7
CAN H
I8
SHIELD
GND
I10
GND
N.C.
CAN L
I9
SHIELD
X3
I10
CAN H
I11
SHIELD
I11
I12
X2
I13
I14
I15
I16
GND
REM OT E I /O
WARNING. If you decide to install an external auxiliary power supply, make sure
that in case of a power outage, the 24 V DC are ensured to brake the motor
under control preventing it from braking by inertia. Ignoring this warning may
cause personal injury.
(
)

( )
N
( )
N
MPC-4xN
MPC-4xN
1
U/U1 V/V1 W/W1
- KM1
- KM2
Delta
MPC-4xN
1
M
3
X/U2 Y/V2 Z/W2
MPC-4xN
MPC-4xN
1
K3
K2
K4
K1
A1
A1
D3
- KA2
D4
Flywheel diode
Flywheel diode
A2
A2
1N4934
1N4934
A1
A1
D3
D4
A2
- KA4
- KA3
A2
K1
K2
EXT ERN AL
AU XI LI ARY
POWER SU PPL Y
1
Star
1
24 V
0 V
0 V
24 V
0 V
24 V
24 V
0 V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents