  Power supplies
Connector description
The regenerative power supply XPS-25 has the following connectors:
2.
94
F. H2/17
Regenerative power supply, XPS-25. Connectors.
1.
2.
DDS
3.
HARDWARE
4.
5.
X1. Connector for inter-module communication.
X2. Connector for the basic control signals.
Ref.1912
X3. Input connector supplying from mains to the auxiliary power supply integrated into the module. The
X4. Output connector of the auxiliary 24 V DC power supply integrated into the module.
X5. Output connector of the auxiliary 24 V DC power supply integrated into the module.
X6. Output connector of the auxiliary 24 V DC power supply integrated into the module.
· 56 ·
L1
CAUTION. AC touch current greater than 3.5 mA.
Install ground wire of at least 10 mm² (Cu) or 16
mm² (Al).
Ri Re L+
CH1
Ri Re L+
2
CH1
Power connector for the three-phase mains.
Power connector for the Ballast resistor connection.
Ground connection for the mains cable.
Power DC BUS supplying power to the modular drives through metal bars.
Connectors for the choke of the XPS-25.
mains power is received through it. It admits a voltage between 400 V AC and 460 V AC.
L2
L3
X1
X4
X5
X6
CH2
CH2
5
3
L1
L2
L3
1
X2
X3
4