Test the C-LAN Connectivity

To test the external IP connections, ping the C-LAN circuit pack and ping a known
1
computer connected to your network. If everything is configured correctly, the Result
column on the Ping Results screen reads PASS. If it reads ABORT, verify the IP-address
information and check the connectivity, including the cabling.
To ping the C-LAN server, type ping ip-address nnn.nnn.nnn.nnn board UUCSS and
2
press
Enter.
The variable nnn.nnn.nnn.nnn is the IP address of the TN799DP C-LAN circuit pack
and UUCSS is the cabinet, carrier, and slot of the TN799DP C-LAN circuit pack.
Type ping ip-address nnn.nnn.nnn.nnn board UUCSS and press
3
The variable nnn.nnn.nnn.nnn is the IP address of another computer beyond the gateway
and UUCSS is the cabinet, carrier, and slot of the TN799DP C-LAN circuit pack.
Test Stratum 3 Clock (if used—S8700
Multi-Connect only)
These procedures test the ability of the Stratum 3 clock to correctly provide timing and alarms
to the media server.
!
CAUTION:
The following procedures are destructive to DS1 data and should not be attempted while
DS1 facilities are active.
Check for Red LEDs
Turn on the Stratum 3 clock and wait 40-50 seconds to allow the system to complete the
1
on-board diagnostics before checking LEDs.
2
If there are any red LEDs, follow the procedures in
Stratum 3 Clock LED Indicators
Card
LED Label
PAI
REF A
PAI
REF B
PAI
ST A
PAI
ST B
Procedure
Check that the CI circuit pack on the left is inserted properly.
Check wiring for DS1 in carrier A which connects the media
gateway to the CSU and the External Synchronization Clock at
the MDF through a Y-cable assembly. If all else fails to clear the
LED then replace the circuit pack.
Check that the CI circuit pack on the right is inserted properly.
Check wiring for DS1 in carrier B which connects the media
gateway to the CSU and the External Synchronization Clock at
the MDF through a Y-cable assembly. If all else fails to clear the
LED then replace the circuit pack.
Replace the ST3 card
Replace the ST3 card
May 2002
Installing the S8700 Multi-Connect
Testing the Complete Configuration
Enter.
"Stratum 3 Clock LED
295
Indicators".