Avaya S8700 Installing Manual page 198

For multi-connnect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

198
Installing the S8700 Multi-Connect
Installing and Wiring Telephones
Auxiliary Lead Appearances at AUX Connector — Continued
Color
Y-BR
BR-Y
Y-S
S-Y
V-BL
BL-V
V-O
O-V
V-G
G-V
V-BR
BR-V
V-S
S-V
1.
Color designation is the main wire color and the color of the stripe on the wire. The
following wire colors apply:
W White
BL Blue
O Orange
G Green
BR Brown
S Slate (Grey)
R Red
BK Black
Y Yellow
V Violet
2.
External alarm with signal incoming to media server.
** External alarm with signal outgoing from media server.
Port Circuit Pack and Telephone Pin Designations
Pin on
Modular
Plug
1
2
3
4
1
Pinouts
44
19
45
20
46
21
47
22
48
23
49
24
50
25
4-wire:
8400-Series,
606A1
TXT
TXR
PXT
Output
GND
-48
GND
-48
GND
-48
Not Connected
Ext Alarm A**
Ext Alarm Return
Not Connected
INADS Tip
INADS Ring
8510T BRI
(with
2-wire: 302D,
adjunct
8400-Series,
speaker
603E
phone)
TXT
T
PXR
May 2002
Power
AUX Power
Analog
Station,
Modem
T
R
NT1
T