Install The 808A Emergency Transfer Panel - Avaya S8700 Installing Manual

For multi-connnect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

808A Emergency Transfer Panel Mounting
Figure notes
1
808A Emergency Transfer Panel
2
Ear for Screw Mount
3
Cut-Out for Snap Mount

Install the 808A Emergency Transfer panel

NOTE:
The 808A must be installed in a location that can be accessed only by authorized
personnel. The location must meet standard environmental considerations such as
temperature, humidity, and so forth.
Verify dial tone is present at each trunk circuit.
1
Locate the circuit start selection switches (see
2
page
216).
These are the first 10 two-position switches on the left side of the Emergency Transfer
Panel. They are used to set each of the five incoming trunk lines to either loop start or
ground start. Two switches are used for each circuit; switches 1 and 2 are used for circuit
1, switches 3 and 4 are used for circuit 2, and so forth. See
page
218.
3
For loop start, set the switches to the left. For ground start, set the switches to the right.
4
Connect a 25-pair cable between the male RJ21 25-pair connector on the Emergency
Transfer Panel and the yellow field of the Main Distribution Frame (MDF).
Assignments for 25-Pair Connector'' on page 219
4
25-Pair Male Connector
5
Circuit Start Switches
''808A Emergency Transfer Panel'' on
shows the pinouts.
May 2002
Installing the S8700 Multi-Connect
Installing and Wiring Telephones
808a_em LJK 042396
''Trunk/Test Switches'' on
''Pin
217