Install Off-Premises Station Wiring

The local telephone company provides cabling outside the building for off-premises stations.
The off-premises stations can appear on any of the RJ21X network interfaces provided for the
Central Office (CO) trunks.
!
CAUTION:
Only an FCC-approved (or equivalent) analog type telephone (such as a 2500-type), can
be used as an off-premises station. The TN746B and TN2183 Analog Line circuit packs
can be connected to off-premises stations.
Install an A25D (male to male) cable between the RJ21X network interface and a sneak
1
fuse panel.
At the Main Distribution Frame (MDF), connect jumper wires between one
2
row/connecting block in the green field and up to three rows/connecting blocks in the
purple field to concentrate the analog line pairs.
Connect an A25D cable between the sneak fuse panel and the terminal block connector
3
associated with the green row in the previous step.
Install a green label on the terminal block to identify the remote location.
4
Administer per the Administrator's Guide for Avaya MultiVantage Software.
5

Off-Premises or Out-of-Building Stations

Out-of-building campus stations are telephones not physically located in the same building as
the equipment room but located on the same property. Only analog telephones connected to
TN742, TN746B, TN2183, or TN769 Analog Line circuit packs can be installed
out-of-building.

Off-Premises Connections

''Connections for 1 to 8 Out-of-Building Analog Telephones'' on page 210
connections for 1 to 8 off-premises analog telephones.
''Connections to 24 Out-of-Building Telephones'' on page 211
24 off-premises analog telephones. Concentrations of analog line pairs are used at both
buildings to minimize the off-premises wiring required. At the MDF, jumpers must be
connected between 1 row/connecting block in the white field and up to 3 rows/connecting
blocks in the purple field. At the station location, a WP-90929, List 1 Concentrator Cable is
used. There are 8 station appearances on each of the 3 fingers of the concentrator cable.
The maximum distance from the media gateway to the out-of-building telephone is 6000 feet
(1828.8 meters) using 24 AWG (#5) (0.5 mm
2
) wire.
May 2002
Installing the S8700 Multi-Connect
Installing and Wiring Telephones
shows the
shows the connections for up to
209