Cable The Stratum 3 Clock - Avaya S8700 Installing Manual

For multi-connnect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

110
Installing the S8700 Multi-Connect
Install the Stratum 3 clock
Composite Clock Timing Output (TOCA) Circuit Pack
Switch
500
OFF
ON
OFF
ON
NOTE:
Set switches 1 and 2 according to the distance from the Stratum 3 clock to the S8700
Media Server for Multi-connect configuration. Set switch 3 to ON. Set switch 4 to OFF.

Cable the Stratum 3 Clock

''Typical Connections to Stratum 3 Clock'' on page 111
3 Clock cabinet. Connections are made through the yellow field cross-connect. A custom "Y"
cable (H600-274) connects the CSU to the DS1 circuit pack and taps off the input for the
Stratum 3 Clock. A resistor built into the cable to provide the necessary isolation between the
S8700 Multi-Connect configuration and the clock. The "Y" cable plugs directly into the CSU
and connects to standard cables for interface to the S8700 Multi-Connect configuration and the
yellow field on the MDF.
The H600-307 cable connects the S8700 Multi-Connect configuration end of the "Y" cable to a
DS1 circuit pack (shown as TN464/2464, TN722, or TN767). The B25A cable connects the
clock end of the "Y" cable to the yellow field on the MDF.
Range
1 ft.
500 ft.
1000
(0.3 m)
(152 m)
OFF
<-----------------------------------------------
--->
OFF
<------------------------------------------------
---->
ON
ON
1000 ft.
1500 ft.
(305 m)
(457 m)
<-------------------------------------------------
--->
<-------------------------------------------------
-->
shows typical connections to a Stratum
May 2002
2000 ft.
2500 ft.
3000 ft.
(610 m)
(762 m)
(914 m)

Advertisement

Table of Contents
loading

Table of Contents