Output Circuits; Connector Terminal Block Converter Unit For 1Cn; Application - YASKAWA SGM Series User Manual

Hide thumbs Also See for SGM Series:
Table of Contents

Advertisement

4.6 Output Circuits

There are two output signals: Brake interlock and servo alarm. They use non-contract transistor cir-
cuits. The voltage and current specifications for these signals are as follows:
Applied Voltage (V max.) ≦ 30 V
Conduction Current (Ip) ≦ 50 mA
Output circuits require 24 VDC power supply by the user. We recommend the same 24 V power sup-
ply as that used for the input circuits.
Output relay
Flywheel diode (Make
sure the diode is facing
the right direction.)

4.7 Connector Terminal Block Converter Unit for 1CN

4.7.1 Application

SERVOPACK
SGD-jjjN
Note
There is no connector terminal block converter unit for the 2CN. We provide encoder cables for
the 2CN connector. Obtain a cable of suitable length (See chapter 9.4 "Cable Specifications.")
SERVOPACK
Transistor
Figure 4.7
Output Circuits
Connector Terminal Block
Converter Unit
JUSP-TA26Pj
Cable
M3.5 Screws
4 -13
Optocoupler
Brake interlock
Servo alarm
Connect to 1CN
4.6 Output Circuits
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents