To reset the Bonded Auth period to its default value, use the following command:
clear dot1x max-req

Managing Other Timers

By default, the switch waits 60 seconds before responding to a client whose authentication
failed, and times out a request to a RADIUS server or an authentication session with a client
after 30 seconds. You can modify these defaults.
Setting the 802.1X Quiet Period
The following command configures the number of seconds a switch remains quiet and does
not respond to a supplicant (client) after a failed authentication:
set dot1x quiet-period seconds
The default is 60 seconds. The acceptable range is from 0 to 65,535 seconds.
For example, type the following command to set the quiet period to 300 seconds:
DWS-1008# set dot1x quiet-period 300
success: dot1x quiet period set to 300.
Type the following command to reset the 802.1X quiet period to the default:
DWS-1008# clear dot1x quiet-period
success: change accepted.
Setting the 802.1X Timeout for an Authorization Server
Use this command to configure the number of seconds before the switch times out a request
to a RADIUS authorization server.
set dot1x timeout auth-server seconds
The default is 30 seconds. The range is from 1 to 65,535 seconds.
For example, type the following command to set the authorization server timeout to
60 seconds:
DWS-1008# set dot1x timeout auth-server 60
success: dot1x auth-server timeout set to 60.
To reset the authorization server timeout to the default, type the following command:
DWS-1008# clear dot1x timeout auth-server
success: change accepted.