Rear View - Omron ZW-C1*T User Manual

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

● Connectors/terminals
No.
Names
16
RS-232C connector
17
Ethernet connector
18
52-pole expansion connector
19
20-pole terminal block
20
Fiber connector
21
ROM connector
22
Frame ground terminal

Rear view

No.
Names
23
DIN track attachment hook
Bottom view
No.
Names
24
Installation hole
ZW User's Manual
Functions
Connect the RS-232C cable when you are connecting the system with a PLC or personal
computer through RS-232C.
For the RS-232C cable, please use the following exclusive products:
If you use a cable not included in the exclusive products, a false operation or breakdown
may result.
• For connecting to a PLC or programmable terminal: ZW-XPT2
• For connecting to a PC: ZW-XRS2
This connector is used to connect with a personal computer through Ethernet.
Prepare commercially available Ethernet cable satisfying the following requirements:
• Category 5e or more, 30 m or less
• RJ45 connector (8-pin modular jack)
• For one-to-one connection: Select cross cable.
• For connection through an industrial switching hub: Select straight cable.
(Recommended hub: W4S1-0@ (Omron))
The 52-pole expansion connector is used to utilize extended functions, such as binary I/
Os, including output for measured value, GATE signal or binary output task number out-
puts, or binary output object task selection input signals; or bank I/O, including bank num-
ber output or bank select input .
A parallel cable for 52-pole extension connector (ZW-XCP2) with 2 m cable is available.
The 20-pole terminal block connects the Sensor Controller DC24 V power supply and
basic I/Os, including output for analog voltage, analog current, judgment, ALARM, BUSY
or ENABLE, or input for ZERO, RESET, TIMING or LED-OFF. The length of Cables
should be less than 30 m.
The fiber connector connects the fiber cable.
The ROM connector connects the calibration ROM.
This is the connector for frame ground. It connects grounding wire.
Functions
Used when fixing the Sensor Controller on DIN track.
Functions
Used when fixing the Sensor Controller with screws.
Part Names and Functions