Hold (auto peak/auto bottom/auto peak-to-peak)
RESET input
Busy output
Judgment output
(HIGH/PASS/LOW)
Binary output
GATE output
Analog output
Item
T3
Response time of analog output
T4
GATE signal rise time
T5
GATE signal output time
T6
TIMING input/RESET input minimum time
T7
Input response time
Explanation of operations
(1) The peak value is updated and the judgment results and binary data are output.
(2) After the judgment result and binary data output, the analog output is updated.
(3) After the judgment result and binary data output, the GATE output is turned ON.
(4) The GATE signal output time after the GATE output is turned ON, the GATE output is turned OFF.
(5) The RESET input is turned ON. During the RESET input minimum time, if the RESET input is turned ON,
the measured value is reset.
(6) The judgment results and binary data are reset. The BUSY output is turned OFF.
(7) After the judgment results and binary data are reset, the analog output is reset.
(8) After the judgment result and binary data output, the GATE output is turned ON.
(9) The GATE signal output time after the GATE output is turned ON, the GATE output is turned OFF.
(10) The RESET input is turned OFF.
(11) The BUSY output is turned ON.
Important
When the setting for non-measurement is "CLAMP", if the sampling value is an abnormal value or an undetermined
*
value
, sampling is not executed. If sampling has been started, it is stopped. The output value is as follows.
• Hold the clamp value.
• If the previous hold value is not the clamp value, the GATE signal is output.
• The BUSY signal is turned OFF.
To start and continue sampling even if a sampling value is an abnormal value or an undetermined value, set "KEEP"
as the non-measurement setting.
*: After the start of measurement, if measurement results are not obtained the number of times required to take the
average, the measurement result is not applied.
158
Parallel I/O connection
(3)
(1) (2)
T4
T5
T3
ON
OFF
ON
OFF
ON
OFF
(4)
Min.
Setting value
(0.1 to 100.0 ms)
3 ms+T0
2 ms+T0
(5)
(6)(7) (8)
(9) (10)
T6
T4
T5
T3
T7
Max.
0.1 ms
0.2 ms
Setting value
(0.1 to 100.0 ms)
3 ms+T0×2
ZW User's Manual
(11)
T7