Omron ZW-C1*T User Manual page 183

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

<Parameter explanation>
Parameter
Description
Task number
Specifies the number of the task of which the measurement result is to be output.
0: TASK1
1: TASK2
2: TASK3
3: TASK4
4: TASK1 to 4
Judgment result acquisition command <JG command>
Acquires the judgment result of the specified task.
<Command format>
J
G
↑ Space
↑ Task number
<Response format>
Normal processing (Task numbers 0 to 3)
(Example) When the judgment result is "HIGH"
CR
1
Judgment result
Normal processing (Task number 4)
(Example) TASK1 judgment result "HIGH", TASK2/TASK3 judgment result "PASS", TASK4 judgment result
"LOW"
1
,
0
When a command was not successfully processed
E
R
CR
<Parameter explanation>
Parameter
Description
Task number
Specifies the number of the task of which the judgment result is to be output.
0: TASK1
1: TASK2
2: TASK3
3: TASK4
4: TASK1 to 4
Judgment result
Displays the judgment result.
PASS: 0
HIGH: 1
LOW: 2
ERROR: 3
ZW User's Manual
CR
,
,
0
2 CR