Operating Mode Switching
MODE
BUSY output
ENABLE output
Judgment output
(HIGH/PASS/LOW)
Binary output
GATE output
Analog output
Item
T3
Response time of analog output
T9
Measurement start response time
Important
In FUN mode, there is no binary output. Immediately after the mode is switched to RUN mode, the clamp value is
output until the measured value is applied.
Explanation of operations
(1) After the mode is switched from RUN to FUN mode, the BUSY output and ENABLE output are turned OFF.
The judgment outputs all go OFF and the binary output is output clamped.
(2) The response time of analog output after the BUSY output is turned ON, the analog output is output
clamped.
(3) After the mode is switched from FUN mode to RUN mode, the BUSY output is turned OFF.
(4) Measurement is restarted and the ENABLE signal is turned ON, then the measurement results are output.
164
Parallel I/O connection
RUN
ON
OFF
ON
OFF
ON
OFF
(1)
(2)
T3
FUN
All OFF
CLAMP
CLAMP
Min.
3 × T0
(4)
(3)
T9
RUN
Max.
0.1 ms
Depends on the set conditions
ZW User's Manual