Omron ZW-C1*T User Manual page 297

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

Item
External inter-
52-pole
Bank
face
extension
connector
LOGGING input
Main functions Exposure time
Measuring cycle
Material setting
Measurement Item
Filtering
Outputs
Display
Number of configurable banks
Task process
System
Rating
Power supply voltage
Current consumption
Insulation resistance
Dialectic strength
Environmental
Degree of protection
immunity
Vibration resistance (destructive)
Shock resistance (destructive)
Ambient temperature
Ambient humidity
Grounding
Material
Weight
Accessories
ZW User's Manual
Specifications
ZW-C10T
Currently
Transistor output system
selected
Output voltage: 21.6 to 30 VDC
bank output
Load current: 50 mA or less
(BANK_OUT
Residual voltage when turning ON: 1.2 V or less
1 to 3)
Leakage voltage when turning OFF: 0.1 mA or less
Bank
DC input system
Selection
Input voltage: 24 VDC ±10% (21.6 to 26.4 VDC)
input
Input current: 7 mA Type. (24 VDC)
(BANK_SEL
ON voltage/ON current: 19 V/3 mA or more
1 to 3)
OFF voltage/OFF current: 5 V/1 mA or less
DC input system
Input voltage: 24 VDC ±10 % (21.6 to 26.4 VDC)
Input current: 7 mA Typ. (24 VDC)
Voltage/Current when turning ON: 19 V/3 mA or more
Voltage/Current when turning OFF: 5 V/1 mA or less
Auto/Manual
500 s to 10 ms
Standard/Mirror/Diffusion surfaces
Height/Thickness/Calculation
Median/Average/Differentiation/High pass/Low pass/Band pass
Scaling/Different holds/Zero reset/Logging for a measured value
Measured value/Threshold value/Analog output voltage or current value/
Judgment result/Resolution/Exposure time
Max. 8 banks
Multi-task (up to 4 tasks per bank)
Save/Initialization/Display measurement information/Communication
settings/Sensor Head calibration/Key-lock/TIMING-key input
21.6 to 26.4 VDC (including ripple)
500 mA max.
Across all lead wires and Sensor Controller case: 20 M (by 250 V megger)
Across all lead wires and Sensor Controller case: 1,000 VAC, 50/60 Hz, 1
min
IP20 (IEC60529)
10 to 55 Hz, 0.35-mm single amplitude, 50 min each in X, Y, and Z directions
2
150 m/s
, 3 times each in six directions (up/down, left/right, forward/
backward)
Operation: 0 to +40C
Storage: -15 to +60C (with no icing or condensation)
Operating and storage: 35 to 85% (with no condensation)
D-type grounding (grounding resistance of 100  or less)
Note: For conventional Class D grounding
Chassis: PC
Approx. 750 g (main unit only)
Instruction sheet,
Member
registration sheet
ZW-C10AT
ZW-C15T
Instruction sheet,
Instruction sheet,
Member
Member
registration sheet
registration sheet
and software for
setting (CD-ROM)
Specifications and External Dimensions
ZW-C15AT
Instruction sheet,
Member
registration sheet
and software for
setting (CD-ROM)
295

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents