Processing unit data acquisition command <DG command>
Acquires the measurement data and setting data of the processing unit.
<Command format>
D
G
Space
<Response format>
Normal processing
Data (N letter)
When a command was not successfully processed
E
R
CR
<Parameter explanation>
Parameter
Unit number
Data number
Important
For unit numbers and data numbers, refer to "10-3 Processing Item Data List" (p.308).
182
No-protocol Connection
CR
Unit number
Space
Data number
CR
Description
Specifies the unit number (0 to 255) to be acquired.
Specifies the data number (0 to 255) to be acquired.