Important
Secure a minimum bending radius (R) for the cable that is at least as large as the specification value. If the bending
radius is smaller than the specification value, this can cause damage to the cable.
Parallel cable
ZW-XCP2
7
B1
B26
Item
Applicable Sensor Con-
troller
Ambient temperature
Ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
(destructive)
Shock resistance
(destructive)
Material
Cross section of flat cable AWG28
Core wire pitch
Cable minimum bending
radius
Weight
Accessories
Important
Secure a minimum bending radius (R) for the cable that is at least as large as the specification value. If the bending
radius is smaller than the specification value, this can cause damage to the cable.
302
Specifications and External Dimensions
(13.1)
6
A1
A26
Specifications
ZW-C@@ series
Operation: 0 to +50C, Storage: -15 to +60C
(No freezing and condensation)
Operation/storage: 35 or 85% RH (No condensation)
1000 VAC, 50/60 Hz, 1 min
20 M (by 250 VDC megger)
10 to 55 Hz (half amplitude 0.35 mm), 50 mins in each of X/Y/Z directions
2
150 m/s
, 6 direction, 3 times each (up/down, left/right, forward/backward)
Cable sheath: PVC
1.27 mm
5.5 mm
Approx. 240 g
Instruction Manual
+170
2200
0
(Unit: mm)
ZW User's Manual