Binary Output
When the judgment results for all tasks are output at the same time (judgment value mode (When
the output target is a judgment value)
The binary output results can be acquired when the GATE output is ON.
Judgment output
(HIGH/PASS/LOW)
Binary output
ON
GATE output
OFF
Item
T0
Measurement cycle
T4
GATE signal rise time
T5
GATE signal output time
T15
Binary output update cycle
Explanation of operations
(1) The TASK2, 3 and 4 judgment results (HIGH/PASS/LOW) are output.
(2) After the judgment result output, the GATE output is turned ON.
(3) The GATE signal output time after the GATE output is turned ON, the GATE output is turned OFF.
(4) After the binary output update cycle, the TASK2, 3 and 4 judgment results are updated.
ZW User's Manual
(1) (2)
(3)
(4)
T15
T4
T0
T5
Judge result
Judge result
Judge result
Min.
0.5 ms
Setting value
(0.1 to 100.0 ms)
T0×Update cycle
Judge result
Judge result
Judge result
Max.
Depends on the set conditions
0.2 ms
Setting value
(0.1 to 100.0 ms)
T0×Update cycle
Parallel I/O connection
Judge result
165