System
setting
[SYSTEM]
(cont'd)
Initialization
Communications
218
Search from Menu Tree
Save
[SAVE]
[INIT]
RS-232C
[COM]
[RS232C]
Ethernet
[ETN]
Delimiter
[DELIMI]
Setting
Option/Setting Range
Save
OK [OK]/Cancel [CAN]
[SAVE]
Initialization
OK [OK]/Cancel [CAN]
[INIT]
Data length
7bit [7BIT]/8bit [8BIT]
[DATA]
*
Parity
None [OFF]
/Odd [ODD]/
[PARITY]
Even [EVEN]
Stop bit
*
1bit [1BIT]
/2 bit [2BIT]
[STOP]
Baud rate
9600/19200/38400
[BAUD.RT]
CS/RS
*
Off [OFF]
/On [ON]
[CS/RS]
IP address 1
[IPADDR]
1 to 233 (default value: 192)
[IP1]
IP address 2
0 to 255 (default value: 168)
[IP2]
IP address 3
0 to 255 (default value: 250)
[IP3]
IP address 4
1 to 254 (default value: 50)
[IP4]
Subnet mask1
[SUBNET]
0 to 255 (default value: 255)
[SUB1]
Subnet mask2
0 to 255 (default value: 255)
[SUB2]
Subnet mask3
0 to 255 (default value: 255)
[SUB3]
Subnet mask4
0 to 255 (default value: 0)
[SUB4]
Subnet mask4
0 to 255 (default value: 0)
[SUB4]
Protocol
Off [OFF]/ TCP/Server [TCP.SV]*/
selection
TCP/Client [TCP.CL]/UDP [UDP]
[PROTCL]
Output IP
address 1
1 to 233 (default value: 192)
[OUTIP]
[IP1]
Output IP
address 2
0 to 255 (default value: 168)
[IP2]
Output IP
address 3
0 to 255 (default value: 250)
[IP3]
Output IP
address 1
1 to 254 (default value: 100)
[IP4]
Port numbers
0 to 65535 (default value: 9601)
[PORT.IN]
Output
destination
0 to 65535 (default value: 9601)
port No.
[PORT.OT]
Delimitter
*
CR [CR]
/LF [LF]/CR+LF [CRLF]
[DELIMI]
Pages
p.255
p.263
*
p.278
*
/57600/115200
p.277
p.280