When a command was not successfully processed/When internal logging is not stopped
E
R
CR
• If internal logging is started without clearing logging data, data is saved end of last logging data.
• When ZW internal memory size is not enough, internal logging is automatically ended. Overwrite is not
executed.
Internal logging data information acquisition command <LI command>
Acquire the internal logging information.
<Command format>
L
I
CR
<Response format>
Normal processing
CR
Operation status
Space
Saved data count
When a command was not successfully processed
E
R
CR
<Parameter explanation>
Parameter
Description
Operation status
Displays the internal logging process status.
0: Internal logging stopped state
1: Internal logging in progress
Saved data count
Displays the number of saved logging data (0 and more).
Data save command <DV command>
Save all bank data and system settings to EEPROM.
<Command format>
D
V
CR
<Response format>
Normal processing
ZW User's Manual