Hold (sampling)
ON
TIMING input
OFF
ON
RESET input
OFF
ON
Busy output
OFF
Judgment output
(HIGH/PASS/LOW)
Binary output
ON
GATE output
OFF
Analog output
Item
T3
Response time of analog output
T4
GATE signal rise time
T5
GATE signal output time
T6
TIMING input/RESET input minimum time
T7
Input response time
Explanation of operations
(1) The TIMING input is turned ON.
(2) During the TIMING input minimum time, when the TIMING input is ON, sampling is started and the BUSY
output is turned ON. The measurement results are sampled and the judgment results and binary data are
output.
(3) After the judgment result and binary data output, the analog output is updated.
(4) After the judgment result and binary data output, the GATE output is turned ON.
(5) The GATE signal output time after the GATE output is turned ON, the GATE output is turned OFF.
(6) The RESET input is turned ON. During the RESET input minimum time, if the RESET input is turned ON,
the measured value is reset.
(7) The judgment results and binary data are reset.
(8) After the judgment result and binary data output, the analog output is reset.
(9) After the judgment result and binary data output, the GATE output is turned ON.
(10) The GATE signal output time after the GATE output is turned ON, the GATE output is turned OFF.
(11) The RESET input is turned OFF.
ZW User's Manual
(1)
(2)
(3)
(4)
T6
T4
T5
T7
T3
Min.
Setting value
(0.1 to 100.0 ms)
3 ms+T0
2 ms+T0
(5)
(6)
(7)
(8)
T4
T7
T3
Max.
0.1 ms
0.2 ms
Setting value
(0.1 to 100.0 ms)
3 ms+T0 × 2
(9)
(10)
(11)
T6
T5
Parallel I/O connection
159