Omron ZW-C1*T User Manual page 149

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

1
Set the operating mode to the FUN mode.
3-3 Switching operation modes p.57
 Explorer pane
 Edit pane
 I/O Setting Screen
2
Select the task from [Output object].
Note
Binary output can also be assigned with key operations on the Sensor Controller.
Output Content Setting p.268
Decimal point digit setting
Sets the number of digits after the decimal point for data output as binary.
Item
Setting item
Binary output
Decimal point
digit
Example:
If the measured value is "0.123456", the output value is as follows according to the number of digits after the
decimal point.
0 digits: 0 (output range: 1048576 mm - 1048575 mm)
1 digit: 1 (output range: 104857.6 mm - 104857.5 mm)
2 digits: 12 (output range: 10485.76 mm - 10485.75 mm)
3 digits: 123 (output range: 1048.576 mm - 1048.575 mm)
4 digits: 1234 (output range: 104.8576 mm - 104.8575 mm)
5 digits: 12345 (output range: 10.48576 mm - 10.48575 mm)
6 digits: 123456 (output range: 1.048576 mm - 1.048575 mm)
If the measurement result is outside the output range, the output range upper or lower limit is output.
For example, if the number of digits after the decimal point is 6 and the measurement result is 2.00000 mm,
the binary output value is 1048575.
If there is a measurement abnormality, the output range upper limit value is output.
ZW User's Manual
: [Bank] | [(Bank Data Name)] (double click)
: [I/O Settings] icon (
: [Binary output]
Setting value
0 digit/1 digit/2 digits/3 digits/4
digits/5 digits (Default value) /6
digits
)
Description
Sets the number of digits after the decimal point for data
output as binary.
Parallel I/O connection
147