Important
When the setting for non-measurement is "CLAMP", if the sampling value is an abnormal value or an undetermined
*
value
, sampling is not executed. If sampling has been started, it is stopped. The output value is as follows.
• Hold the clamp value.
• If the previous hold value is not the clamp value, the GATE signal is output.
To start and continue sampling even if a sampling value is an abnormal value or an undetermined value, set "KEEP"
as the non-measurement setting.
*: After the start of measurement, if measurement results are not obtained the number of times required to take the
average, the measurement result is not applied.
ZW User's Manual
Parallel I/O connection
157