Omron ZW-C1*T User Manual page 219

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

I/O setting
Binary output
[I/O]
[BINARY]
(cont'd)
Data output
setting
[COM.OUT]
LOGGING
[PAR.LOG]
Bank setting
[BANK]
ZW User's Manual
Data output
setting
[COM.OUT]
Decimal point
digit
[DEC.NUM]
Output cycle
[CYCLE]
GATE Period
[GATE]
Bank change
[BK.CHG]
Bank mode
[BK.MODE]
Bank copy
[BK.COPY]
Bank clear
[BK.CLR]
Setting
Option/Setting Range
Measurement value 1 [MEAS1]
(TASK1(ON*/OFF), TASK2 to TASK4
Output object
(ON/OFF*))/Measurement value 2
[OUTPUT]
[MEAS2]/Judgment value [JUDGE]/
Off [OFF] *
TASK1 to 4
[TASK1] to
Off [OFF] */On [ON]
[TASK4]
Decimal point
0 [0DIG] to 6 [6DIG] (Default: 5
digit
[5DIG])
[DEC.NUM]
Output cycle
1 to 100 (Default: 1)
[CYCLE]
GATE Period
0.1 to 100.0 ms (Default: 0.1)
[GATE]
Output data
format
ASCII[ASCII]*/Binary[BINARY]
[FORMAT]
Number of
integer digits
1 / 2 / 3 / 4 /5*
[INT.NUM]
Fractional
digits
0 / 1 / 2 / 3 / 4 / 5 / 6*
[DEC.NUM]
Leading zeros
suppressed.
Off* /On
[ZEROSP]
None [NO]*/Comma [COMMA]/
Field
Tab [TAB]/Space [SPACE]/
separator
CR[CR]/LF[LF]/CR+LF[CRLF]/
[FIELD]
Semicolon [SEMICO]
None [NO]*/Comma [COMMA]/
Record
Tab [TAB]/Space [SPACE]/
separator
CR[CR]/LF[LF]/CR+LF[CRLF]/
[RECORD]
Semicolon [SEMICO]
Save intervals
0 to1000
[INTRVL]
Save count
0 to12800
[COUNT]
Bank1 [BANK1] to Bank8 [BANK8]
Bank number
(default value: Bank1) Up to Bank32
[BANK]
can be selected when the bank mode
is "JUDGE".
Bank mode
Normal [NORMAL]
[BK.MODE]
Judgment value [JUDGE]
Copy source
Bank1 [BANK1] to Bank8 [BANK8]
[FROM]
Copy destination
Bank1 [BANK1] to Bank8 [BANK8]
[TO]
Bank clear
Ok [OK]/Cancel [CAN]
[BK.CLR]
Search from Menu Tree
Pages
p.268
p.268
p.269
p.270
p.270
p.275
p.275
p.252
*
/
p.253
p.254
p.256
217

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents