Setting the Zero Reset Type
Set the zero reset type.
Item
Setting item
Zero reset
Zero reset type
 Explorer pane
 Edit pane
 Task Settings window : [Zero reset]
1
Set [Status] to ON.
Setting the Status p.101
Important
The zero reset type can be set only when [Status]
is set to ON.
2
Select the zero reset type from [Type].
Note
The zero reset type can also be set by the operating keys on the Sensor Controller.
Setting the Zero Reset Mode p.250
ZW User's Manual
Setting value
Description
Real value
Sets the measured value when a zero reset is executed to zero.
Sensor head
Zero reset
Hold value
Sets the measured value (hold value) when a zero reset is executed to zero.
This is enabled when hold measurement is performed.
Sensor head
: [Bank] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Measurement of height
from reference surface
Reference A
Hold A
(reference)
Zero reset
Direction of movement
)
Setting the Output Conditions
Measurement of height
from reference surface
103