Processing Item Data List - Omron ZW-C1*T User Manual

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

10-3 Processing Item Data List

Unit
Processing Item Data
number
0
Image input
1
Exposure time
(Note
control
1)
(When 2 area
mode is OFF)
20
Measurement
object
(Note 1) When using exposure time control with 2 area mode ON,
Area 1 exposure time control: Unit number "4"
Area 2 exposure time control: Unit number "5"
308

Processing Item Data List

Parameter
number
0
Measuring cycle
22
2 area mode
23
Area tracking mode
30
Start direction of count
measurement surfaces
39
Surface subject to area
tracking (Reference surface)
40
Surface subject to area
tracking (Tracking surface)
193
2 area teaching
0
Exposure time control mode
2
Surface subject to exposure
time control
6
Exposure time fixed value
14
Exposure time upper limit
36
Exposure time
37
Received light amount (1
surface)
38
Received light amount (2
surfaces)
39
Received light amount (3
surfaces)
40
Received light amount (4
surfaces)
1
Material
4
Background removal level
default
Setting range/output range Acquisition
value
2000
500 to 10000 (s)
0
0: OFF
1: ON
0
0: Tracking OFF
1: Start point tracking
2: End point tracking
3: End point/start point
tracking
0
0: NEAR
1: FAR
0
0: SUR.1ST
1: SUR.2ND
2: SUR.3RD
3: SUR.4TH
4: LIGHT PEAK
1
0: SUR.1ST
1: SUR.2ND
2: SUR.3RD
3: SUR.4TH
4: LIGHT PEAK
1: Execute
0
0: Auto
1: Fixed
4
0: SUR.1ST
1: SUR.2ND
2: SUR.3RD
3: SUR.4TH
4: LIGHT PEAK
1000
1 to 5000 (s)
1000
1 to 5000 (s)
1000
1 to 5000 (s)
0 to 4095 (Gradation)
0 to 4095 (Gradation)
0 to 4095 (Gradation)
0 to 4095 (Gradation)
0
0: Normal
1: Mirror surface
2: Diffusion surface
100
0 to 4095 (Gradation)
Setting
Yes/No
Yes/No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Yes
Yes
Yes
ZW User's Manual

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents