Omron ZW-C1*T User Manual page 165

Displacement sensor zw series confocal fiber type
Hide thumbs Also See for ZW-C1*T:
Table of Contents

Advertisement

Zero reset
ON
ZERO input
OFF
Judgment output
(HIGH/PASS/LOW)
Item
T7
Input response time
T13
ZERO input time
T14
ZERO input cancel time
Explanation of operations
(1) The ZERO input is turned ON.
(2) After the ZERO input time, the ZERO input is turned OFF.
(3) After the ZERO input is turned OFF, the zero reset is executed and the judgment results reflected in the
measurement results are output.
(4) The ZERO input is turned ON.
(5) After at least the cancel time of ZERO input has passed, the zero reset is cancelled.
ZW User's Manual
(1)
(2)
(3)
T13
T7
Min.
2 ms+T0
50 ms
1 s
(4)
T14
Max.
3 ms+T0×2
0.8s
Parallel I/O connection
(5)
163