1H-8 Ignition System:
Ignition Coil Resistance
• Disconnect the spark plug caps. Refer to "Spark Plug
Cap and Spark Plug Removal and Installation
(Page 1H-4)".
• Measure the ignition coil resistance in both the
primary and secondary windings. If the resistance is
not within the standard range, replace the ignition coil
with a new one.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Resistance (Ω)
Ignition coil resistance
Primary: 1 – 5 Ω ((+) terminal – (–) terminal)
Secondary: 25 – 40 kΩ (Plug cap – Plug cap)
( )
(–)

CKP Sensor Inspection

Refer to "Electrical Components Location in Section 0A
(Page 0A-7)".
CKP Sensor Peak Voltage
1) Remove the left frame side cover. Refer to "Exterior
Parts Removal and Installation in Section 9D
(Page 9D-5)".
2) Remove the left frame lower cover. Refer to "Exterior
Parts Removal and Installation in Section 9D
(Page 9D-5)".
3) Disconnect the CKP sensor lead wire coupler (1)
and connect the multi-circuit tester with the peak volt
adaptor.
NOTE
Be sure that all of the couplers are connected
properly and the battery is fully-charged.
4) Connect the multi-circuit tester with the peak volt
adaptor as follows:
CAUTION
!
Before using the multi-circuit tester and peak
voltage adaptor, refer to the appropriate
instruction manual.
Special tool
Tester knob indication: Voltage (
CKP sensor
I940H1180012-01
B940H21806006
2. CKP sensor coupler
3. CKP sensor
5) Measure the CKP sensor peak voltage in the
following procedures:
a) Shift the transmission into neutral, turn the
ignition switch ON and grasp the clutch lever.
b) Press the starter button and allow the engine to
crank for a few seconds, and then measure the
CKP sensor peak voltage.
6) Repeat the b) procedure several times and measure
the highest CKP sensor peak voltage.
CKP sensor peak voltage
3.0 V and more (Bl – G)
(A): 09900–25008 (Multi-circuit tester set)
(+) Probe
BI
BI
G
3
4. Peak voltage adaptor
1
I940H1180013-03
)
(–) Probe
G
2
4
(A)
I940H1180018-01

Advertisement

Table of Contents