Installation
Install the air cleaner chamber in the reverse order of
removal. Pay attention to the following points:
• Fit the throttle body clamps properly. Refer to "Throttle
Body Construction (Page 1D-10)".
• Route the hoses properly. Refer to "Throttle Body
Construction (Page 1D-10)".
• Connect the IAP sensor coupler and IAT sensor
coupler.
• Align the mark "A" of the air cleaner case and convex
part "B" of the joint tube.
"A"
"B"
I940H1140012-01
• Connect the ISC hoses (1) and ISC connector (2).
1
• Install the joint tube to the air cleaner chamber. Refer
to "Throttle Body Construction (Page 1D-10)".
• Tighten the clamp screws (3)
3
Engine Mechanical:
1D-8
2
I940H1140019-02
3
I940H1140020-03