DTC "C60" (P0480): Cooling Fan Relay Circuit Malfunction

Detected Condition and Possible Cause
Detected Condition
Cooling fan relay signal is not input to ECM.
Wiring Diagram
ECM
24
FAR
Troubleshooting
CAUTION
!
When using the multi-circuit tester, do not strongly touch the terminal of the ECM coupler with a
needle pointed tester probe to prevent terminal damage.
NOTE
After repairing the trouble, clear the DTC using SDS tool. Refer to "Use of SDS Diagnosis Reset
Procedures (Page 1A-13)".
Cooling fan relay
G/R
O/B
To the side-
stand switch
Cooling fan motor
ECM coupler (Harness side)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Engine General Information and Diagnosis:
Possible Cause
• Cooling fan relay circuit open or short.
• ECM malfunction.
Side-stand
relay
16