H2: Multi-Function Digital Outputs - YASKAWA L1000A Technical Manual

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

5.7 H: Terminal Functions
Setting 58: High speed limit down
When this input is closed the speed in down direction will be limited to the leveling speed. No speed limit is applied when
the car is going up.
Setting 5C: Stop Distance Correction
When this terminal closes and a direct landing is selected for the stopping method (S5-10 = 1), the drive will stop at the
designated floor with greater accuracy.
Setting 67: Communication test mode
The drive has a built-in function for self-diagnosing serial communications operation. The test involves wiring the send
and receive terminals of the RS-485/422 port together. The drive transmits data and then confirms that the
communications are received normally. Refer to
Setting 79: Brake feedback
This input allows the drive to monitor the brake operation and issue a fault if the brake status does not match the brake
command (digital output set to H2-

◆ H2: Multi-Function Digital Outputs

H2-01 to H2-05: Terminals M1-M2, M3-M4, M5-M6, P1-PC, and P1-P2 Function Selection
The drive has three multi-function output terminals.
01 through H2-05.
No.
H2-01
Terminals M1-M2 Function Selection
H2-02
Terminals M3-M4 Function Selection
H2-03
Terminals M5-M6 Function Selection
H2-04
Terminals P1-C1 Function Selection (photocoupler)
H2-05
Terminals P2-C2 Function Selection (photocoupler)
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-set Speed Agree 1
4
Speed Detection 1
5
Speed Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
9
Speed Reference Source
A
Up/Down Command Source
B
Torque Detection 1
E
Fault
F
Not used (Through Mode)
10
Minor Fault
11
Fault Reset Command Active
12
Timer Output
13
Speed Agree 2
14
User-set Speed Agree 2
15
Speed Detection 3
16
Speed Detection 4
18
Torque Detection 2
188
Refer to Stop Distance on page 370
Self-Diagnostics on page 410
= 50).
Parameter Name
Table 5.12 Multi-Function Digital Output Terminal Settings
Function
Page
189
189
189
190
190
190
191
191
191
191
191
192
192
192
192
192
192
192
193
193
193
192
for details.
Table 5.12
lists the functions available for theses terminals using H2-
Setting
1A
During Reverse
1B
During Baseblock 2 (N.C.)
1C
Motor 2 Selection
1D
During Regeneration
1E
Restart Enabled
1F
Motor Overload Alarm (oL1)
20
Drive Overheat Pre-alarm (oH)
2F
Maintenance Period
30
During Torque Limit
33
Within Position Lock Bandwidth
37
During Frequency Output
50
Brake Control
51
Output Contactor Control
52
Door Zone Reached
53
Not Zero Speed
54
Light Load Direction
55
Light Load Direction Detection Status
56
Cooling Fan Status
57
Input Phase Loss
58
Safe Disable Status
61
Motor Pole Search Status
100 to 161
Functions 0 to 61 with Inverse Output
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
for details on how to use this function.
Setting Range
0 to 161
50: Brake control
0 to 161
51: Output control contactor
0 to 161
6: Drive ready
0 to 161
37: During frequency output
0 to 161
F: Through Mode
Function
Default
Page
194
194
194
194
194
195
195
195
195
195
195
195
195
196
196
196
196
196
196
196
196
196

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents