B.3 Parameter Table
No. (Addr.)
Name
S5-12
Stop Distance
(6B2H)
S5-13
Direct Landing Minimum Speed
(6D6H)
Level
<36> When the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 650.00 inches.
<37> When the length units are set for inches (o1-12 = 1), the setting range becomes 0.00 to 393.00 inches.
S6: Error Detection
No. (Addr.)
Name
S6-01
Motor Contactor Response Error
(6B3H)
(SE1) Detection/Reset Selection
S6-02
Starting Current Error (SE2)
(6B4H)
Detection Delay Time
S6-04
Output Current Error (SE3)
(6B6H)
Detection Delay Time
S6-05
Brake Response Error (SE4)
(6B7H)
Detection Time
S6-10
Overacceleration Detection Level
(6B8H)
S6-11
Overacceleration Detection Time
(6B9H)
S6-12
Overacceleration Detection
(6BAH)
Selection
S6-15
Speed Reference Loss Detection
(6BBH)
S6-16
Restart after Baseblock Selection
(6BCH)
<7> Default setting value is determined by the digital operator display unit selection (o1-03). The default is normally 1.5 m/s
the default becomes 5.0 ft/s

◆ T: Motor Tuning

Enter data into the following parameters to tune the motor and drive for optimal performance
T1: Induction Motor Auto-Tuning
No. (Addr.)
Name
T1-01
Auto-Tuning Mode Selection
(701H)
T1-02
Motor Rated Power
(702H)
T1-03
Motor Rated Voltage
(703H)
370
V/f
OLV
Sets the stopping distance when Stop Distance Control is enabled.
V/f
OLV
Sets the speed level for the start of Direct Landing.
Direct Landing is essentially disabled if the starting speed for Direct Landing is less than the
maximum output speed multiplied by this parameter (E1-04 × S5-13).
All Modes
0: Detect during stop, SE1 must be manually reset
1: Detect during stop, SE1 can be automatically reset
2: No SE1 detection
V/f
OLV
Sets a delay time for detecting SE2.
V/f
OLV
Sets a delay time for detecting SE3.
All Modes
Sets a delay time for detecting SE4.
V/f
OLV
If the elevator car accelerates at an abnormal rate, the drive triggers an overspeed fault (dv6)
and has the motor coast to stop. Parameter S6-10 determines the acceleration rate that triggers a
fault.
V/f
OLV
Sets a primary delay for detecting overacceleration.
V/f
OLV
0: Always enabled
1: During run only
All Modes
Enabled or disables detection for speed reference missing (FrL).
0: Disabled
1: Enabled
All Modes
0: No restart after Baseblock/Safe Torque-Off
1: Restart after Baseblock/Safe Torque-Off
2
(Setting Range: 0.0 to 50.0 ft/s
V/f
OLV
0: Rotational Auto-Tuning
1: Stationary Auto-Tuning 1
2: Stationary Auto-Tuning for Line-to-Line Resistance
4: Stationary Auto-Tuning 2
V/f
OLV
Sets the motor rated power as specified on the motor nameplate.
Note: Use the following formula to convert horsepower into kilowatts: kW = HP x 0.746.
V/f
OLV
Sets the motor rated voltage as specified on the motor nameplate.
Description
CLV
CLV/PM
CLV
CLV/PM
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
2
).
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Setting
Page
common_
Default: 0 mm
TMonly
Min: 0 mm
Max: 10000 mm
<37>
common_
TMonly
Default: 20%
Min: 0%
Max: 100%
Setting
Page
common_
TMonly
Default: 0
Min: 0
Max: 2
common_
Default: 200 ms
TMonly
Min: 0.00 ms
Max: [S1-04]-[S1-06]
common_
Default: 200 ms
TMonly
Min: 0 ms
Max: 5000 ms
common_
Default: 500 ms
TMonly
Min: 0 ms
Max: 10000 ms
common_
TMonly
Default:
<7>
Min: 0.0 m/s2
Max: 20.0 m/s2
<7>
common_
Default: 50 ms
TMonly
Min: 0 ms
Max: 5000 ms
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 1
Min: 0
Max: 1
common_
Default: 0
TMonly
Min: 0
Max: 1
2
, but when o1-03 = 6,
Setting
Page
common_
TMonly
Default: 0
<5>
Min: 0
Max: 4
<18>
common_
Default:
<4>
TMonly
Min: 0.00 kW
Max: 650.00 kW
common_
Default: 200.0 V
<9>
TMonly
Min: 0.0 V
Max: 255.0 V
<9>
xx
xx
245
245
245
245
245
246
246
246
246
110
110
110

Hide quick links: