A.1 Three-Phase 200 V Class Drives
A.1 Three-Phase 200 V Class Drives
Item
CIMR-L 2A
Maximum Applicable Motor Capacity (HP)
Input Current (A)
Rated Voltage
Rated Frequency
Input
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Input Power (kVA)
Rated Output Capacity (kVA)
Rated Output Current (A)
Overload Tolerance
Output
Carrier Frequency
Maximum Output Voltage (V)
Maximum output speed (Hz)
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater
than the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring
connections, and power supply impedance.
<3> Rated motor capacity is calculated with a rated output voltage of 220 V.
<4> Carrier frequency can be set up to 8 kHz while keeping this current rating. Higher carrier frequency settings require derating.
<5> Carrier frequency can be set up to 5 kHz while keeping this current rating. Higher carrier frequency settings require derating.
<6> Carrier frequency is set to 2 kHz. Higher carrier frequency settings require derating
328
Table A.1 Power Ratings (Three-Phase 200 V Class)
0018
0025
0033
5
7.5
10
<1>
18.9
28
37
<2>
9.5
14
18
6.7
9.5
12.6
<3>
17.5
25
33
<4>
<4>
<4>
User adjustable between 2 and 15 kHz
Specification
0047
0060
0075
0085
15
20
25
30
52
68
80
82
Three-phase 200 to 240 Vac 50/60 Hz/270 to 340 Vdc
-15 to 10%
±5%
27
36
44
37
17.9
23
29
32
47
60
75
85
<4>
<4>
<4>
<4>
150% of rated output current for 60 s
Three-phase 200 to 240 V (proportional to input voltage)
120 Hz (user-set)
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
0115
0145
0180
0215
0283
40
50
60
75
111
136
164
200
51
62
75
91
44
55
69
82
115
145
180
215
<4>
<5>
<5>
<5>
User adjustable between 2 and 10 kHz
0346
0415
100
125
150
271
324
394
124
148
180
108
132
158
283
346
415
<5>
<5>
<6>