N: Advanced Performance Set-Up - YASKAWA L1000A Technical Manual

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

B.3 Parameter Table
No. (Addr.)
Name
L8-29
Current Unbalance Detection
(4DFH)
(LF2)
L8-35
(4ECH)
Installation Selection
<1>
L8-38
Automatic Torque Boost Selection
(4EFH)
L8-39
Reduced Carrier Frequency
(4F0H)
L8-55
Internal Braking Transistor
(45FH)
Protection
L8-62
Operation Selection at Input Phase
(529H)
Loss
L8-77
Oscillation Suppression
(61EH)
L8-88
Safe Disable Operation Mode
(2F5H)
<1> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Default setting is determined by the drive model (o2-04).

◆ n: Advanced Performance Set-Up

The n parameters are used to adjust more advanced performance characteristics such as speed feedback detection, Online
Tuning for motor line-to-line resistance, and PM motor control tuning.
n2: Speed Feedback Detection Control (AFR) Tuning
No. (Addr.)
Name
n2-01
Speed Feedback Detection Control
(584H)
(AFR) Gain
n2-02
Speed Feedback Detection Control
(585H)
(AFR) Time Constant 1
n2-03
Speed Feedback Detection Control
(586H)
(AFR) Time Constant 2
n5: Inertia Compensation
No. (Addr.)
Name
n5-01
Inertia Compensation Selection
(5B0H)
n5-02
Motor Acceleration Time
(5B1H)
362
V/f
OLV
0: Disabled
1: Enabled
All Modes
0: IP00 enclosure drive
2: IP00 enclosure drive with top protective cover
All Modes
Torque Boost increases the output current limit while decreasing the carrier frequency when the
output current exceeds a certain value.
0: Disabled
3: Enabled
All Modes
Sets the reduced carrier frequency used by the Torque Boost function.
All Modes
0: Disabled. L8-55 should be disabled when using a regen converter or an optional braking unit.
1: Protection enabled.
All Modes
Sets stopping method when a Input phase loss fault (PF) occurs. See parameter L8-05.
0: Ramp to Stop - Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to Stop
2: Fast Stop - Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only - Drive continues operation.
All Modes
Used to suppress speed oscillations that occur with an unloaded motor and that have the same
frequency as the output frequency.
All Modes
0: Mode 0
1: Mode 1
V/f
OLV
Sets the internal speed feedback detection control gain in the automatic frequency regulator
(AFR).
If hunting occurs, increase the set value. If response is low, decrease the set value.
V/f
OLV
Sets the time constant used for speed feedback detection control (AFR).
V/f
OLV
Sets the AFR time constant to be used during regen.
V/f
OLV
0: Disabled
1: Enabled
V/f
OLV
Sets the time required to accelerate the motor at 100% torque from 0 to the nominal speed.
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
CLV
CLV/PM
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
Description
CLV
CLV/PM
CLV
CLV/PM
Setting
Page
common_
Default: 1
TMonly
Min: 0
Max: 1
common_
Default:
<4>
TMonly
Min: 0
Max: 2
common_
TMonly
Default: 0
Min: 0
Max: 3
Default: 3.0 kHz
common_
TMonly
Min: 1.0 kHz
Max: 15.0 kHz
common_
Default: 1
TMonly
Min: 0
Max: 1
common_
TMonly
Default: 1
Min: 0
Max: 3
common_
Default: 0
TMonly
Min: -100
Max: 100
common_
Default: 1
TMonly
Min: 0
Max: 1
Setting
Page
common_
TMonly
Default: 1.00
Min: 0.00
Max: 10.00
common_
Default: 50 ms
TMonly
Min: 0 ms
Max: 2000 ms
common_
Default: 750 ms
TMonly
Min: 0 ms
Max: 2000 ms
Setting
Page
common_
Default: 0
TMonly
Min: 0
Max: 1
common_
Default:
<4>
TMonly
Min: 0.001 s
Max: 10.000 s
214
214
215
215
215
212
216
216
217
217
217
218
218