5.7 H: Terminal Functions
Setting 90 to 97: DriveWorksEZ Digital Input 1 to 8
These settings are for digital inputs functions used in DriveWorksEZ. Changing these settings is not typically required.
Setting 9F: DriveWorksEZ Disable
This function is used to enable or disable a DriveWorksEZ program in the drive. An input programmed for this function is
effective only if A1-07 = 2.
Status
Open
Closed
u

H2: Multi-Function Digital Outputs

n
H2-01 to H2-03: Terminal M1-M2, M3-M4, and M5-M6 Function Selection
The drive has three multi-function output terminals.
H2-02, and H2-03.
No.
H2-01
H2-02
Terminal M3-M4 Function Selection (open-collector)
H2-03
Terminal M5-M6 Function Selection (open-collector)
Setting
0
During Run
1
Zero Speed
2
Speed Agree 1
3
User-Set Speed Agree 1
4
Frequency Detection 1
5
Frequency Detection 2
6
Drive Ready
7
DC Bus Undervoltage
8
During Baseblock (N.O.)
9
Frequency Reference Source
A
Run Command Source
B
Torque Detection 1 (N.O.)
C
Frequency Reference Loss
D
Braking Resistor Fault
E
Fault
F
Through Mode
10
Minor Fault
11
Fault Reset Command Active
12
Timer Output
13
Speed Agree 2
14
User-Set Speed Agree 2
15
Frequency Detection 3
16
Frequency Detection 4
17
Torque Detection 1 (N.C.)
18
Torque Detection 2 (N.O.)
19
Torque Detection 2 (N.C.)
1A
During Reverse
1B
During Baseblock (N.C.)
1C
Motor 2 Selection
218
Parameter Name
Terminal M1-M2 Function Selection (relay)
Table 5.34 Multi-Function Digital Output Terminal Settings
Function
Description
DriveWorksEZ enabled
DriveWorksEZ disabled
Table 5.34
lists the functions available for theses terminals using H2-01,
Page
Setting
219
1D
During regeneration
219
1E
Restart Enabled
219
1F
Motor Overload Alarm (oL1)
220
20
Drive Overheat Pre-Alarm (oH)
220
22
Mechanical Weakening Detection
221
2F
Maintenance Period
221
30
During Torque Limit
221
31
During Speed Limit
222
32
During Speed Limit in Torque Control
222
33
Zero Servo Complete
222
37
During Frequency Output
222
38
Drive Enabled
222
39
Watt Hour Pulse Output
222
3C
LOCAL/REMOTE Status
222
3D
During Speed Search
222
3E
PID Feedback Low
222
3F
PID Feedback High
222
4A
During KEB Operation
223
4B
During Short Circuit Braking
223
4C
During Fast Stop
223
4D
oH Pre-Alarm Time Limit
223
4E
Braking Transistor Fault (rr)
224
4F
Braking Resistor Overheat (rH)
60
Internal Cooling Fan Alarm
222
61
Rotor Position Detection Completed
222
90
DriveWorksEZ Digital Output 1
224
91
DriveWorksEZ Digital Output 2
225
92
DriveWorksEZ Digital Output 3
225
100 to 192 Functions 0 to 92 with Inverse Output
YASKAWA ELECTRIC SIEP C710616 31B YASKAWA AC Drive – A1000 Technical Manual
Setting Range
0 to 192
0: During run
0 to 192
1: Zero Speed
0 to 192
2: Speed agree 1
Function
Default
Page
225
225
225
225
225
225
225
226
226
226
226
226
226
226
227
227
227
227
227
227
227
227
227
227
227
227
227